This product is specially designed for water purifier, which can replace traditional high-low pressure switch. It is more sensitive action and used for wider range of applications.
Dedicated to water purifiers, replacing traditional high and low voltage switches for water purifiers.
More sensitive response and wider applicability.
| Pressure Set Range (Gauge Pressure) | From0.02MPa to1.0 MPa;below0.6MPa is considered low-pressure, while 0.6MPa andaboveisconsideredhighpressure |
| Burst Pressure | 3.2MPa x 1min, no damage orleakage |
| Mechanical Lifespan (Switching Cycles) | 100,000 |
| Mechanical Lifespan (Switching Cycles) | 30,000 |
| Electrical Overview | |
| Switching Load | 24...250 VAC / 0.02...6A; 8...36 VDC /0.02...3 A Under the condition of ensuring electrical lifespan without pressure The difference switch, the maximum current is 0.5A |
| Operating Conditions | |
| Medium | Air, water |
| Temperature | Ambient: -40...+65°C[-40...+149°F](Low pressure), -40...+120°C[-40...+248°F](High pressure) Medium:-40...+80'C[-40...+176°F](Low pressure); -40...+135°C[-40...+275°](High pressure) |
| IP Grade | IP54 |